You are using unvalidated product, Click here to support us
https://journal.unhas.ac.id/index.php/eksitasi/issue/feed JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO 2023-07-28T07:29:38+00:00 Open Journal Systems <p>Jurnal Eksitasi DTE-UH (JE-DTE-UH) mempublikasikan hasil-hasil penelitian dalam bidang Teknik Elektro yang meliputi bidang Teknik Tenaga Listrik, Telekomunikasi, Komputer dan Sistem Kendali serta berbagai isu-isu lainnya terkait perkembangan terbaru dari teknologi pada bidang Teknik Elektro.</p> <p><strong>e-ISSN : 2829-5110</strong></p> https://journal.unhas.ac.id/index.php/eksitasi/article/view/27116 Pemodelan Harga Energi Tanpa Rugi Jaringan Pada Sistem Tenaga Terkongesti 2023-06-09T06:34:05+00:00 Muhammad Bachtiar Nappu bachtiar@eng.unhas.ac.id <p>Paper ini menyajikan konsep dasar pemodelan harga nodal di pasar listrik yang kompetitif dan untuk mengatasi kemacetan, tetapi menyederhanakan metode dan memiliki transparansi yang dapat diterima sehingga dapat mengirimkan sinyal ekonomi dengan benar kepada pelaku pasar. Harga nodal yang diwakili oleh strategi penyelesaian berbasis model harga <em>locational marginal price </em>(LMP) dilakukan dalam lingkungan pasar listrik yang kompetitif untuk menetapkan jumlah uang yang diterima oleh perusahaan pembangkitan dari operator sistem dan dibayarkan kepada operator sistem dari pelanggan. Makalah ini menginvestigasi formulasi model LMP dengan mengabaikan rugi-rugi jaringan menggunakan aliran daya optimal DC (DC-OPF). Dalam pendekatan ini, model LMP merepresentasikan harga energi dan biaya kongesti transmisi. Penerapan metode yang diusulkan pada sistem 3-bus dan hasilnya diteliti dalam makalah ini.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO https://journal.unhas.ac.id/index.php/eksitasi/article/view/27113 Analisis Kestabilan Frekuensi Pada Sistem Sulbagsel Dengan Integrasi PLTA Bakaru II 2023-06-09T05:42:28+00:00 Firda Fajryani Kamil kamilff18d@student.unhas.ac.id Zaenab Muslimin zaenab@unhas.ac.id Indar Chaerah Gunadin indar@eng.unhas.ac.id <p>Rencana Usaha Penyediaan Tenaga Listrik (RUPTL) PT PLN (Persero) 2021-2030 memuat rencana perubahan sistem kelistrikan Sulawesi Bagian Selatan (Sulbagsel) salah satunya pembangunan PLTA Bakaru II dengan kapasitas 140 MW. Disisi lain, integrasi PLTB sebelumnya, membuat frekuensi sistem berosilasi. Oleh karena itu dilakukan simulasi kestabilan frekuensi pada sistem Sulbagsel menggunakan <em>software</em> Digsilent untuk melihat bagaimana kontribusi integrasi PLTA Bakaru II yang memiliki inersia yang lebih besar, dalam meredam osilasi frekuensi sistem. Penelitian dilakukan dengan mensimulasikan kestabilan frekuensi sistem Sulbagsel pada berbagai macam skenario. Hasil simulasi penelitian ini yaitu frekuensi naik menjadi 50.202 Hz setelah integrasi PLTA Bakaru II dilakukan, dan turun menjadi 49.867 Hz ketika PLTA Bakaru II lepas sinkron. Namun frekuensi tersebut masih dalam batas toleransi frekuensi yang diizinkan. Sedangkan ketika skenario fluktuasi PLTB, ketika PLTB tidak membangkitkan daya, frekuensi sistem sebelum integrasi PLTA Bakaru II turun menjadi 49.909 Hz, sedangkan setelah integrasi PLTA Bakaru II sebesar 49,944 Hz. Ketika PLTB berada dalam pembangkitan maksimum, frekuensi sistem sebelum integrasi PLTA Bakaru II naik menjadi 50,183 Hz, sedangkan setelah integrasi PLTA Bakaru II sebesar 50,162 Hz.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO https://journal.unhas.ac.id/index.php/eksitasi/article/view/27111 Rancang Bangun Earth Resistivity Meter Data Logger Berbasis Miikrokontroller 2023-06-09T05:19:29+00:00 Muhammad Irsan Sadri irsan.sadri42@gmail.com Zaenab Muslimin zaenab@unhas.ac.id Indar Chaerah Gunadin indar@eng.unhas.ac.id <p class="Abstract"><span lang="EN-US">Pengukuran resistivitas merupakan aspek penting dari karakterisasi dan pengukuran material. Saat ini, proses pencatatan data resistivitas secara manual memakan waktu, rawan kesalahan, dan kurang akurat. Perancangan resistivity meter yang dibuat pada penelitian ini menggunakan data logger berbasis mikrokontroler yang memudahkan pengguna alat merekam data dalam mencari resistivitas seperti tegangan dan arus. Keunggulan utama perancangan ini terletak pada perekaman data secara otomatis yang didesain multichannel. Dengan adanya alat ini diharapkan dapat membuat penelitian menjadi lebih efisien dengan mengurangi waktu dan tenaga yang digunakan dalam proses pengambilan data resistivitas tanah. Metode penelitian ini meliputi proses perancangan dan pengujian alat. Kinerja alat dilakukan dengan membandingkan hasil pelacakan berdasarkan data yang direkam oleh alat dengan menggunakan konfigurasi dua elektroda. Konstruksi elektroda yang digunakan adalah konfigurasi Wenner dan konfigurasi Dipol kemudian dievaluasi akurasi data logger dari resistivity meter yang dirancang menggunakan aplikasi ResIPy. Konfigurasi Wenner dan Dipol masing-masing menghasilkan 84 dan 520 konfigurasi elektroda dan penggambaran bawah tanah dengan akurasi terbaik sebesar +/- 2,5% dan +/- 1,5. Dimana untuk nilai resistivitas konfigurasi Wanner yang berhasil didapatkan berdasarkan data yang dicatat oleh alat berada pada kisaran 3,0 log10 Ohm.m sampai dengan 0,2 log 10 Ohm.m untuk pengukuran di lapangan dan 310,7 Ohm.m sampai dengan 1, 9 Ohm.m untuk pengukuran di laboratorium. Adapun konfigurasi dipol-dipol berada dikisaran 3,3log10 Ohm.m sampai dengan 0,2log 10 Ohm.m untuk pengukuran lapangan dan 235,9 Ohm.m sampai 12,3 Ohm.m untuk pengukuran di laboratorium.</span></p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO https://journal.unhas.ac.id/index.php/eksitasi/article/view/27117 Optimasi Penentuan Letak Pembangkit Tersebar (Distributed Generation) Pada Sistem Distribusi Radial Dengan Adanya Kapasitor 2023-06-09T06:41:21+00:00 Siti Annisa Syalsabila syalsabila18d@student.unhas.ac.id Ardiaty Arief ardiaty@eng.unhas.ac.id Tajuddin Waris tajuddin@unhas.ac.id <p>Pembangkit terdistribusi atau <em>Distributed&nbsp; Generation </em>(DG) &nbsp;adalah pembangkit berkapasitas lebih kecil dibandingkan pembangkit listrik utama. DG &nbsp;&nbsp;terinjeksi langsung&nbsp; pada&nbsp; sistem distribusi&nbsp; dan terletak di dekat pusat-pusat beban.&nbsp; Pemasangan&nbsp; DG&nbsp; dirancang&nbsp; untuk&nbsp; memperoleh rugi-rugi daya minimum dan profil tegangan berada pada batasannya. Metode optimasi yang digunakan dalam penelitian ini adalah Algoritma Penyerbukan Bunga atau <em>Flower Pollination Algorithm</em> (FPA). Penelitian ini diujikan pada SDR 33 bus dengan standar IEEE yang memperhatikan adanya kapasitor pada sistem.&nbsp; Hasil&nbsp; analisis&nbsp;&nbsp; dari penelitian ini diperoleh bahwa pemasangan <em>multi</em> DG dan dengan ukuran kapasitor yang lebih besar di SDR lebih optimal dalam memperoleh rugi-rugi daya minimum dan&nbsp;&nbsp; profil tegangan berada pada batasannya dengan lokasi DG yang sama.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO https://journal.unhas.ac.id/index.php/eksitasi/article/view/27115 Hasanuddin University Training Center and Convention Hotel Electrical Installation Study 2023-06-09T06:23:15+00:00 Andi Muh Iqbal Firaldi iqbalfiraldi10@gmail.com Ansar Suyuti asuyuti@unhas.ac.id Fitriyanti Mayasari fitriyantimaya@unhas.ac.id <p>The increasing demand for electric power, especially in the field of electrical installations, requires a technically reliable plan. A good electrical installation system in the building must comply with the Indonesian National Standard (SNI) and General Electrical Installation Regulations (PUIL), so that electrical installations in buildings can work effectively and efficiently and can overcome disturbances that occur in the process of distribution network or distributing electricity to the building. The overall study of the electrical installation at the Training Center and Convention Hotel, Hasanuddin University aims to determine the feasibility of the electrical installation system with the most recent PUIL standards. The method used in this study started with collecting the data, calculating the required illumination value according to the function of each room, and determining the type of conducting CRC installed in the building. The results of this study for data processing obtained the number of required illumination values ​​installed using the lumen method equation, where the number of armatures varies according to the function of each room. The diameter of the current carrying capacity (KHA) used in a conductor is NYM 5 x 185 mm2, with the value of the current flowing in the main KHA is 389.22 A, and the total power used in the building is 221.781 Watt with installed loads such as air conditioners, lighting, and electric sockets. The control system, protection system, and earthing system contained in the building can be said to be operating correctly and meets PUIL 2011 standards.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO https://journal.unhas.ac.id/index.php/eksitasi/article/view/27112 Studi Koordinasi Relai Arus Lebih Pada Sistem Proteksi Generator dan Transformator PLTA Bakaru 2023-06-09T05:29:25+00:00 Abd Rahim abdulrahim199911@gmail.com Indar Chaerah Gunadin indar@eng.unhas.ac.id Yustinus Upa Sombolayuk sombolayuk@unhas.ac.id <p>Saat ini kebutuhan masyarakat akan ketersediaan listrik sangatlah penting. Oleh karena itu, negara berkewajiban untuk memenuhi ketersediaan listrik bagi masyarakat dengan cara membangun pembangkit yang handal agar dapat memasok kebutuhan listrik dengan baik. Seiring berjalannya waktu, peningkatan beban sistem tentunya akan mempengaruhi tingkat keandalan perangkat proteksi. Oleh karena itu, peralatan proteksi harus diperbarui di beberapa titik untuk memiliki sistem proteksi dengan keandalan tinggi. Pada penelitian ini memiliki tujuan untuk mendapatkan settingan dan koordinasi relai arus lebih yang tepat pada sistem kelistrikan khususnya genarator dan transformator PLTA Bakaru. Berdasarkan hasil dari plot kurva relai arus lebih pada generator dan transformator masih terdapat kekurangan yaitu mengalami overlap, untuk mengatasi hal tersebut maka perlu dilakukan adanya resetting. Setelah dilakukan resetting, plot kurva relai arus lebih pada generator dan transformator sudah tidak mengalami overlap. Hasil simulasi menggunakan software setelah dilakukan resetting menunjukkan bahwa koordinasi antara relai arus lebih pada generator dan transformator utama serta beban pemakaian sendiri PLTA Bakaru sudah bekerja dengan baik, dimana ketika terjadi gangguan di dalam zona transformator utama maka koordinasi relai yang bekerja terlebih dahulu yaitu relai yang paling dekat dengan gangguan disebut relai pertama.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO https://journal.unhas.ac.id/index.php/eksitasi/article/view/27110 Perencanaan Pelepasan Beban Dengan Analisis Eigenvalue dan Eigenvector 2023-06-09T04:51:43+00:00 Ardiaty Arief ardiaty@eng.unhas.ac.id <p>Sejak tahun 1920-an, kestabilan sistem tenaga listrik telah diidentifikasi sebagai persyaratan utama untuk pengoperasian sistem tenaga listrik yang aman dan andal. Ketidakstabilan tegangan dapat membawa seluruh sistem jaringan ke keadaan penurunan tegangan yang signifikan, oleh karena itu tindakan pencegahan diperlukan. Salah satu cara yang ekonomis untuk mencegah jatuh tegangan atau <em>voltage collapse</em> adalah pelepasan beban atau <em>under voltage load shedding</em> (UVLS), dimana pengurangan beban kecil antara 5% dan 10% dari total beban sistem dapat menjaga kestabilan sistem. Pelepasan beban akibat tegangan rendah atau <em>under voltage</em> memegang peranan penting dalam sistem kendali tenaga listrik ketika sistem mengalami gangguan yang besar. Pengurangan beban telah digunakan sejak lama sebagai alternatif terakhir untuk mencegah kegagalan sistem tenaga utama yang diaktifkan oleh relai <em>under</em><em>-frequency</em> atau relai <em>under</em><em>-voltage</em>. Makalah ini mengusulkan metode berdasarkan analisis modal untuk pelepasan beban yang menggunakan <em>eigenvalue</em> dan <em>eigenvector</em> kemudian menghitung faktor partisipasi bus untuk menentukan lokasi pelepasan beban. Penelitian ini mengkaji keefektifan faktor partisipasi dalam menentukan lokasi pelepasan beban.</p> <p>Kata Kunci: analisis modal, eigenvalue, faktor partisipasi, kestabilan tegangan, pelepasan beban.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 JURNAL EKSITASI DEPARTEMEN TEKNIK ELEKTRO https://journal.unhas.ac.id/index.php/eksitasi/article/view/27731 Pengaruh Difusi Air Terhadap Dielektrik Dan Hidrofobik Pada Material Elastomer Silikon 2023-07-19T12:37:50+00:00 Satrianto Magu’ga satriamaguga@gmail.com Salama Manjang salamamanjang@unhas.ac.id Hasniaty A hasniaty@unhas.ac.id <p>Salah satu peralatan pendukung sistem distribusi tenaga listrik adalah isolator listrik. Fungsi isolator listrik sangat menentukan dalam menjamin kelancaran transmisi energi listrik dengan mengisolasi penghantar tegangan tinggi dari penghantar lainnya. Keunggulan isolator polimer antara lain sifat dielektrik, resistivitas volume, sifat termal, kekuatan mekanik, dan ringan. Isolator polimer juga memiliki sifat hidrofobik, yang memungkinkan mereka mempertahankan sifat hidrofobiknya bahkan ketika terkena lapisan polusi. Untuk menentukan pengaruh difusi air pada sifat dielektrik dan hidrofobik elastomer silikon, persentase penyerapan air yang mempengaruhi sudut kontak dan permitivitas relatif ditentukan. Kekuatan dielektrik dan sudut kontak memainkan peran penting dalam menentukan kualitas isolator yang digunakan dalam sistem tenaga. Pada penelitian ini sampel elastomer silikon dengan filler SiO2 dan ATH direndam pada suhu ruang dan suhu 50°C sesuai standar IEC. Penelitian ini juga melibatkan pengujian data kualitatif. Hasil penelitian menunjukkan bahwa konsentrasi bahan pengisi yang diberikan berpengaruh terhadap tingkat penyerapan air oleh sampel. Dengan bertambahnya berat sampel, sudut kontak yang diperoleh cenderung lebih kecil, tetapi semua sampel masih menunjukkan sifat hidrofobik.<br>Selain itu, temuan penelitian juga menunjukkan bahwa dengan bertambahnya berat sampel, nilai permitivitas relatif<br>cenderung lebih tinggi, tetapi pada kondisi tertentu, nilai permitivitas relatif dapat lebih rendah.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023 https://journal.unhas.ac.id/index.php/eksitasi/article/view/27970 Implementasi Otomasi Sistem Palang Parkir Berbasis Teknologi RFID pada Lahan Parkir Rektorat Unhas 2023-07-28T07:29:38+00:00 Ida Rachmaniar Sahali idar@unhas.ac.id Muh Anshar anhar@ft.unhas.ac.id Zulkifli Arfah zulkifli.arfah@gmail.com <p>Pengelolaan lahan parkir Rektorat Universitas Hasanuddin masih menggunakan tenaga manusia dalam menjaga gerbang masuk dan keluar parkir kendaraan. Pada kasus ini rawan terdapat kesalahan dalam otorisasi pengguna yang dapat menggunakan lahan parkir tersebut. Penelitian ini akan merancang otomasi sistem palang parkir menggunakan<br>teknologi RFID dan mengimplementasikannya pada lahan parkir Rektorat Universitas Hasanuddin. Hasil pengujian diperoleh jarak maksimum pembacaan kartu RFID sebesar 9cm dengan posisi kartu sejajar dengan reader; pengujian waktu pembacaan empat node dihitung dari ditempelkannya kartu hingga teraktivasinya relay pada sistem diperoleh waktu rata-rata sebesar 0.373 detik; Untuk pengujian waktu penggunaan sistem dimana waktu mulai dihitung dari pengendara melakukan tap kartu pada reader lalu pengendara melewati palang parkir hingga palang menutup kembali secara sempurna; diperoleh waktu untuk Node 1 selama 6.81 detik, Node 2 selama 18.56 detik, Node 3 selama 11.04 detik, dan Node 4 selama 14.13 detik.</p> 2023-06-09T00:00:00+00:00 Hak Cipta (c) 2023