Performance of Cool Box Based on Thermoelectric Cooler (TEC) Using Circulation of Heat Dissipation
Main Article Content
Abstract
This research discusses performance of cool box based on Thermoelectric Cooler (TEC) using circulation of heat dissipation. The advantage of implementing circulation of heat dissipation is optimize performance of cold side of peltier element. Cool box has capacity of 6L with the dimension of 45 x 36 x 26 cm. Circulation of heat dissipation consists of some components such as water block, radiator, and pump. While cooling components used are peltier element TEC1-12706, DC fan, and coldsink. The cool box temperature measurement results without load for ± 3 hours show coldsink temperature stably at 10°C and 16°C for room temperature. While the results of temperature measurement with 6L load show coldsink temperature stably at 15°C and room temperature of 20°C for ± 3 hours. Air volume flow rate for coldsink temperature circulator of 0,0640 m3/s and air mass flow rate of 0,0768 kg/s whereas air volume flow rate for heat dissipation fan of 0,0224 m3/s and 0,0269 kg/s for air mass flow rate.
Downloads
Article Details
This work is licensed under a Creative Commons Attribution 4.0 International License.
Allow anyone to modify, improve, and make derivative works, even for commercial purposes, as long as they credit to you for the original work.
References
T. R. Buntu, F. P. Sappu, and B. L. Maluegha, "Analisis Beban Pendinginan Produk Makanan Menggunakan Cold Box Mesin Pendingin LUCAS NULLE TYPE RCC2," Jurnal Online Poros Teknik Mesin, vol. 6, pp. 20-31, 2017.
N. M. Sitakar, Nurliana, F. Jamin, M. Abrar, Z. H. Manaf, and Sugito, "Pengaruh Suhu Pemeliharaan dan Masa Simpan Daging Ikan Nila (Oreochromis niloticus) Pada Penyimpanan Suhu -20C Terhadap Jumlah Total Bakteri, " Jurnal Medika Veterinaria, pp. 162-165.
Munawir, M. N. Sasongko, and N. Hamidi, "Unjuk Kerja Cool Box Berbasis Thermolektrik Cooler dengan Single dan Multi-Stage Termoelektrik," Jurnal Rotor, vol. 12, pp. 28-32, 2019.
Munawir. M. N. Sasongko, and N. Hamidi, "Kinerja Thermoelectric Pada Kotak Pendingin Berdasarkan Rangkaian Thermoelectric dan Putaran Fan Wind Tunnel, vol. 12, pp. 27-40, 2021.
A. K. Mainil, A. Aziz, and M. Akmal, "Portable Thermoelectric Cooler Box Performance with Variation of Input Power and Cooling Load," Aceh International Journal of Science and Technology, vol. 7, pp. 85-92, 2018.
Amrullah, "Rancang Bangun Cooler Box Berbasis Termoelektrik Dengan Variasi Heatsink," Jurnal Teknologi Terpadu, vol. 1, pp. 59-64, 2021.
I. Rosyadi, Haryadi, N. Pratama, M. H. Fasya, A. Irman, Aswata, Y. Yusuf, "Analisis perancangan cooler box berbasis termoelektrik terhadap varian penggunaan termal paste, faktor lingkungan, dan heatsink," Journal Industrial Servicess, vol. 7, pp.188-192, 2021.
H. Munnik, D. Yohannes, and Y. Bekti, "Pemanfaatan Peltier untuk Cooler Box Mini," Jurnal Teknologi Industri, vol. 11, 2022.
Sabiqunassabiqun, Z. Djafar, and W. H. Piarah, "Performance of TEC Cascade on Input Voltage Variations in Fish Cooler Box," EPI International Journal of Engineering, vol. 5, pp. 44-49, 2022.
B. Permana and I. M. Arsana, "Aplikasi Pendingin Elektrik TEC1-12706 dengan Water Cooling Pada Cooler Box Semikonduktor," Jurnal Rekayasa Mesin, vol.4, pp.61-66, 2017.
K. U. Bramantyo and I. M. Arsana, Aplikasi Pendingin Elektrik TEC1-12706 dan TEC1-12715 dengan Heatsink Pada Cooler Box Semi Konduktor," Jurnal Rekayasa Mesin, vol. 5, pp.153-158, 2019.
I. A. Sormin, I. B. P. Gunadnya, and I. G. N. A. Aviantara, "Kinerja Kotak Pendingin (Cooler Box) Berpendingin TEC1-12715 Pada Beberapa Beban Pendinginan," Jurnal Beta (Biosistem dan Teknik Pertanian), vol. 11, pp. 29-37, 2023.