Design of Heat Pump Water Heater (HPWH) System on Km. Meratus Karimata
Main Article Content
Abstract
The need for hot water on a ship is one of the facilities that must be obtained by the crew while carrying out their duties on the KM. Meratus Karimata is one of the ships that provide hot water as a facility for crew members. The heating system on this ship still uses the EHHW (Electric Heating Hot Water) heating system which will then be changed to the HPWH (Heat Pump Water Heater) system. This hot water need is based on the MLC (Marine Labor Convention) regarding the provision of recreational facilities on deck accommodation. The provision of hot water needs to be calculated and designed. The first thing to do is to calculate all distribution support components. Then the data for the needs of pumps with a power of 0.504 Kw, valves, shower taps, sink taps, pipe connections, and SCH 40 pipes with a diameter of ¾ "and 1" are obtained. After that, the design is carried out using software assistance. After the design is carried out, the calculation of component costs is carried out with details of the valve price of IDR 10,129,000, pipe IDR 5,186,000, pipe connection IDR 1,751,000, supply pump IDR 1,150,000, HPWH 95,300,000. The price of EHHW and HPWH is a difference of IDR 21,300,000, which is more expensive for HPWH. However, in the calculation of fuel consumption, HPWH is more efficient with HPWH fuel consumption data of 0.11 liters/hour at a cost of Rp.1,249 / hour, while fuel consumption for EHHW is 0.77 liters/hour at a cost of Rp.10,116/ hour.
Downloads
Article Details
This work is licensed under a Creative Commons Attribution 4.0 International License.
Allow anyone to modify, improve, and make derivative works, even for commercial purposes, as long as they credit to you for the original work.
References
Rifaldo, M Irfan.2019. “Analisa Teknis Sistem Hpwh (Heat Pump Water Heater) Pada Km. Meratus Karimata “. SKRIPSI. Surabaya.
Chairbowo Fajri & Ichsani Djatmiko.2017. “Rancang Bangun dan Studi Eksperimen Alat Penukar Panas untuk Memanfaatkan Energi Refrigerant Keluar Kompresor AC sebagai Pemanas Air pada ST/D= 8 dengan Variasi Volume Air”. Jurnal Teknik ITS, 5(2).
Jokosisworo, S.2012.” Studi Komparasi Pipa SCH 40 Galvanize dengan SCH 40 Non Galvanize pada Sistem Pipa Ballast Dikaji dari Segi Teknis dan Ekonomis” Jurnal Teknik Perkapalan UNDIP, 7(3).
Mulyadi.1990.” Analisa Dalam Perhitungan Biaya Untuk Membangun Sebuah Perusahaan Dari Segi Ekonomi” Jogjakarta.
Kalinci Yildiz & Hepbasli Arif.2009. “A review of heat pump water heatingsystems “. Renewable and Sustainable Energy Reviews, 13(6-7), 1211-1229
Andriyan.2018.” Tugas Merancang IV” [LAPORAN]. Surabaya
Binus, Ibnu.2010.” Feasibility Theory Studi Kelayakan Bisnis” Palu.
Neksa Petter & Zakeri Reza.1998. “CO2-heat pump water heater: characteristics, system design and experimental results “. International Journal of refrigeration, 21(3), 172-179.